1. | Reset the GFCI Breaker by turning it to OFF and then back ON again. |
2. | Check to see if the GFCI Breaker Trips Again. |
Note: Most intermittent GFCI trips are due to either a Faulty Heater or a Faulty Ozone Generator.
3. | If the GFCI did Not Trip Again, Select "GFCI did Not Trip Again" Below. If it Did Trip, Continue to Step 4. |
GFCI did Not Trip Again
4. | Disconnect Both Heater Straps from the System Board "HTR1" and "HTR2" Terminals. |
5. | Reset the GFCI Breaker by turning it to OFF and then back ON again. |
6. | Did the GFCI Breaker Trip Again, after Disconnecting the Heater Straps from the System Board?. |
YES NO
|