Adding a Device |
|
Example: Adding The Heater. Enter Configuration Mode, and once Setup is Verified, the Setup Devices Screen will appear. 1. Scroll Down to Heater, and Move Right to the Next Screen.
2. On Add Device, Move Right to Add the Heater.
3. On Mode, Select the Pool/Spa Mode that you want the Heater to Operate in (Pool, Spa or Pool + Spa).
4. Scroll Down to Device Type, and Select Relay.
5. Scroll Down to Maximum Speed, and Select On/Off.
6. Scroll Down to Output 1, and Select Internal. The Heater Cannot be Setup to be External.
7. Scroll Down to Expansion Boxes, and Do Not attempt to Change the Value. The Heater Cannot be Connected to an Expansion Box.
8. Scroll Down to Device No., and Select Relay Number 10 if the Heater is Wired to the TB3 LOW VOLTAGE HEATER Terminal Block. If the Heater is connected to one of the Other Relays, Select the Relay Number 2-8 that the Heater is Wired to.
9. Scroll Down to Output 2 on the Next Screen, and Do Not attempt to Change the Value.
10. Scroll Down to Expansion Boxes, and Do Not attempt to Change the Value.
11. Scroll Down to Device No., and Do Not attempt to Change the Value.
12. Scroll Down to Freeze Protect, and Select Disable.
13. Scroll Down to Valves, and Select Disable.
14. Scroll Down to Cooling Time, and Select 7 Min. for how long the Heater Requires to Cool before the Filter Pump shuts Off. Other Values can be Selected if Required by Heater Manufacturer.
15. Scroll Down to Rename Device on the Next Screen, and Move Right to Spell and Save the New Device Name.
16. Navigate Left, Right, Up, and Down to the Desired Letter, and Select the Letter to Spell your New Name. When the New Name is Complete, Select Save to Save the New Name.
Continue To Adding The Pool Light Continue To Exiting Configuration Mode |