Setting Filter Cycles |
|
You will be Configuring the Filter 1 Filter Cycles for the Pool. Note: If you have two totally Separate bodies of water that Share the same equipment, Configure the Filter 2 Filter Cycles for the Spa. 1. From the Display Screen on the Wireless Panel, Move Right to the Main Menu.
2. Scroll Down to Setup, and Move Right to the Setup Screen.
3. With Filter Cycles Highlighted , Move Right to the Filter Cycle Setup Screen.
4. With Filter 1 Highlighted , Move Right to Setup the First Two Filter Cycles.
5. With Filter Timers Highlighted , Press Select to Enable Filter 1 Filter Cycles.
6. Scroll Down to Device Type, and Select the Pool/Spa Mode that you want the Filter Cycle to Operate in (Pool or Spa). The Filter 1 Timers should be set to Pool.
7. Scroll Down to Days To Run, and Move Right to the Next Screen to Select Days To Run.
8. Select All Days, or Scroll Down to Select Weekends, Weekdays, or you can Select the Days Individually. Move Left to Save and Exit the Days To Run Screen.
9. Scroll Down to Timer 1 Start, and Press Select to Set the Timer 1 Start Time.
10. With the Hour Flashing. use the Up and Down Buttons to select the Hour. Then Press Select to Save and Move to the Minutes.
11. With the Minutes Flashing, use the Up and Down Buttons to select the Minutes. Then Press Select to Save and Complete Timer 1 Start Time Setting.
12. Move Left to Exit Timer 1 Start Time Setting.
13. Scroll Down to Timer 1 Stop, and Press Select to Set the Timer 1 Stop Time.
14. With the Hour Flashing. use the Up and Down Buttons to select the Hour. Then Press Select to Save and Move to the Minutes.
15. With the Minutes Flashing, use the Up and Down Buttons to select the Minutes. Then Press Select to Save and Complete Timer 1 Stop Time Setting.
16. Move Left to Exit Timer 1 Stop Time Setting.
17. Scroll Down to Pump Speed, and Select High or Low Speed for the Timer 1 Filter Cycle.
18. Scroll Down to Timer 2 on the Next Screen, and Press Select to Enable Timer 2.
19. Scroll Down to Timer 2 Start, and Press Select to Set the Timer 2 Start Time.
20. With the Hour Flashing. use the Up and Down Buttons to select the Hour. Then Press Select to Save and Move to the Minutes.
21. With the Minutes Flashing, use the Up and Down Buttons to select the Minutes. Then Press Select to Save and Complete Timer 2 Start Time Setting.
22. Move Left to Exit Timer 2 Start Time Setting.
23. Scroll Down to Timer 2 Stop, and Press Select to Set the Timer 2 Stop Time.
24. With the Hour Flashing. use the Up and Down Buttons to select the Hour. Then Press Select to Save and Move to the Minutes.
25. With the Minutes Flashing, use the Up and Down Buttons to select the Minutes. Then Press Select to Save and Complete Timer 2 Stop Time Setting.
26. Move Left to Exit Timer 2 Stop Time Setting.
27. Scroll Down to Pump Speed, and Select High or Low Speed for the Timer 2 Filter Cycle. Then Move Left to Exit Filter 1 Setup.
28. Scroll Down to Yes, and Press Select to Save the Filter 1 Filter Cycle Timers.
29. Continue with Additional Filter Cycle Setup, or Move Left to Exit the Filter Cycle Setup Screen.
30. Continue with Additional Setup, or Move Left to Exit the Setup Menu.
31. Move Left again to Exit the Main Menu.
Continue To Heater Settings Return To Panel Operation Index |