Check the Ozone Generator & Other Options

1.If there was an Ozone Generator Connected to the System Board, we will Check that Next.  If there was No Ozone Generator Connected to the System Board, Continue to Step 7.
2.Turn OFF the Power to the System.
3.Connect the Ozone Generator to the System Board.
4.Turn ON the Power to the System.
5.In Priming Mode ("Pr" Displayed), Turn ON the Ozone Generator by Pressing the "Mode" Button.  The Ozone Generator will remain ON for 15 Seconds.
6.If the GFCI Trips with the Ozone Generator ON, Remove and Replace the Ozone Generator, and then Retest.  If the GFCI does Not Trip, Continue to Step 7.

Ozone Generator has been Replaced - Retest

7.If there were any Other Lights or Options Connected to the System Board, we will Check those Next.  Repeat Steps 8 thru 13 for each Light or Option that was Connected.  If there was No Other Lights  or Options Connected to the System Board, Continue Test.
8.Turn OFF the Power to the System.
9.Connect the Light or Option to the System Board.
10.Turn ON the Power to the System.
11.Press Any Temp Button to Exit Priming Mode ("Pr" Display turns OFF).
12.Turn ON the Light or Option.
13.If the GFCI Trips with the Light or Option ON, Remove and Repair or Replace the Light or Option, and then Retest.  If the GFCI does Not Trip, Continue Test.

Light or Option has been Repaired or Replaced - Retest

GFCI did Not Trip - Continue Test