1. | If there was an Air Blower Connected to the System Board, we will Check that Next. If there was No Air Blower Connected to the System Board, Continue to Step 7. |
2. | Turn OFF the Power to the System. |
3. | Connect the Air Blower to the System Board. |
4. | Turn ON the Power to the System. |
5. | In Priming Mode ("Pr" Displayed), Turn ON the Air Blower to the Highest Speed. |
6. | If the GFCI Trips with the Air Blower ON, Remove and Replace the Air Blower, and then Retest. If the GFCI does Not Trip, Continue to Step 7. |
Air Blower has been Replaced - Retest
7. | If there was a Circ Pump Connected to the System Board, we will Check that Next. If there was No Circ Pump Connected to the System Board, Continue Test. |
8. | Turn OFF the Power to the System. |
9. | Connect the Circ Pump to the System Board. |
10. | Turn ON the Power to the System. |
11. | In Priming Mode ("Pr" Displayed), Turn ON the Circ Pump if it is Not already ON. The Circ Pump may turn ON with Pump 1 Low. |
12. | If the GFCI Trips with the Circ Pump ON, Remove and Replace the Circ Pump, and then Retest. If the GFCI does Not Trip, Continue Test. |
Circ Pump has been Replaced - Retest
GFCI did Not Trip - Continue Test
|