1. | If there was a 12 Volt Spa Light Connected to the System Board, we will Check that Next. If there was No Spa Light Connected to the System Board, Continue to Step 8. |
2. | Turn OFF the Power to the System. |
3. | Connect the Spa Light to the System Board. |
4. | Turn ON the Power to the System. |
5. | Press Any Temp Button to Exit Priming Mode ("Pr" Display turns OFF). |
6. | Turn ON the Spa Light to the Brightest Setting. |
7. | If the GFCI Trips with the Spa Light ON, Remove and Repair or Replace the Spa Light, and then Retest. If the GFCI does Not Trip, Continue to Step 8. |
Spa Light has been Repaired or Replaced - Retest
8. | If there was a Fiberoptic Light Connected to the System Board, we will Check that Next. If there was No Fiberoptic Light Connected to the System Board, Continue Test. |
9. | Turn OFF the Power to the System. |
10. | Connect the Fiberoptic Light to the System Board. |
11. | Turn ON the Power to the System. |
12. | Press Any Temp Button to Exit Priming Mode ("Pr" Display turns OFF). |
13. | Turn ON the Fiberoptic Light and Color Wheel. |
14. | If the GFCI Trips with the Fiberoptic Light and Color Wheel ON, Remove and Repair or Replace the Fiberoptic Light, and then Retest. If the GFCI does Not Trip, Continue Test. |
Fiber Light has been Repaired or Replaced - Retest
GFCI did Not Trip - Continue Test
|