Check the Spa Light and Fiberoptic Light

1.If there was a 12 Volt Spa Light Connected to the System Board, we will Check that Next.  If there was No Spa Light Connected to the System Board, Continue to Step 8.
2.Turn OFF the Power to the System.
3.Connect the Spa Light to the System Board.
4.Turn ON the Power to the System.
5.Press Any Temp Button to Exit Priming Mode ("Pr" Display turns OFF).
6.Turn ON the Spa Light to the Brightest Setting.
7.If the GFCI Trips with the Spa Light ON, Remove and Repair or Replace the Spa Light, and then Retest.  If the GFCI does Not Trip, Continue to Step 8.

Spa Light has been Repaired or Replaced - Retest

8.If there was a Fiberoptic Light Connected to the System Board, we will Check that Next.  If there was No Fiberoptic Light Connected to the System Board, Continue Test.
9.Turn OFF the Power to the System.
10.Connect the Fiberoptic Light to the System Board.
11.Turn ON the Power to the System.
12.Press Any Temp Button to Exit Priming Mode ("Pr" Display turns OFF).
13.Turn ON the Fiberoptic Light and Color Wheel.
14.If the GFCI Trips with the Fiberoptic Light and Color Wheel ON, Remove and Repair or Replace the Fiberoptic Light, and then Retest.  If the GFCI does Not Trip, Continue Test.

Fiber Light has been Repaired or Replaced - Retest

GFCI did Not Trip - Continue Test