1. | If there was an Ozone Generator Connected to the System Board, we will Check that Next. If there was No Ozone Generator Connected to the System Board, Continue to Step 7. |
2. | Turn OFF the Power to the System. |
3. | Connect the Ozone Generator to the System Board. |
4. | Turn ON the Power to the System. |
5. | In Priming Mode ("Pr" Displayed), Turn ON the Ozone Generator by Pressing the "Mode" Button. The Ozone Generator will remain ON for 15 Seconds. |
6. | If the GFCI Trips with the Ozone Generator ON, Remove and Replace the Ozone Generator, and then Retest. If the GFCI does Not Trip, Continue to Step 7. |
Ozone Generator has been Replaced - Retest
7. | If there were any Other Lights or Options Connected to the System Board, we will Check those Next. Repeat Steps 8 thru 13 for each Light or Option that was Connected. If there was No Other Lights or Options Connected to the System Board, Continue Test. |
8. | Turn OFF the Power to the System. |
9. | Connect the Light or Option to the System Board. |
10. | Turn ON the Power to the System. |
11. | Press Any Temp Button to Exit Priming Mode ("Pr" Display turns OFF). |
12. | Turn ON the Light or Option. |
13. | If the GFCI Trips with the Light or Option ON, Remove and Repair or Replace the Light or Option, and then Retest. If the GFCI does Not Trip, Continue Test. |
Light or Option has been Repaired or Replaced - Retest
GFCI did Not Trip - Continue Test
|