Configuration Settings - HANDLE WITH CARE!

Most EL Systems can make use of Configuration Settings. Configuration Settings are enabled when the CFG Jumper on the circuit board is on 2 pins. These settings can be viewed on the panel and are accessed when DIP switch A10 is turned ON while spa is powered up and running. The system will enter the Edit Menu for Configuration Settings.

IMPORTANT: When employed, these settings are factory configured. Changing them may cause a CFE error that could be impossible to recover from. Use cautions when reviewing or making changes. Always use a HOT SHEET or other verified reference when determining proper Configuration Settings.

When DIP switch A10 is turned ON while spa is powered up and running, the system will enter the Edit Menu for Configuration Settings.

Press any Temperature button to scroll through the list of settings.

Press Jets 1 on the main control panel to select a Feature. The Configuration Setting will flash.

Press the any Temp button to scroll through the various Configuration Settings for the Feature.

Press Jets 1 to select a Configuration and return to the Feature List.

The Configuration Setting will stop flashing.

Press Temp to continue scrolling the list

Continue until all settings are chosen.

Press any Light button to exit the Configuration Settings Menu

Turn DIP Switch A10 to the OFF (down) position.

Spa will automatically begin to run with the new settings.

Do NOT start up the spa with A10 turned on or the CFE error will occur.

CFE errors are illegal configurations such as a pump and a blower set to run on the same output.  The configuration must be corrected before the spa will operate.